Current consumption |
<50 mA (incl. amplifier) |
output signal |
4…20 mA,CANopen, CANopen Safety, 2.5…7.5V DC |
Safety overload |
(150%)200% of nominal load |
Measuring body plastic change point |
(200%)300% of nominal load |
Fracture point * |
(300%)500% of nominal load |
Temperature drift |
0.1%/10K |
0.1%/10K |
0.1%/10K |
Linear error * |
<0.3% FS |
<0.5~1%FS |
<0.3% FS |
Lag error * |
<0.5% FS |
<1%FS |
<0.5% FS |
connector * |
M12 or CANNON |
M12 or CANNON |
M12 or CANNON |
Material |
Stainless steel |
Stainless steel |
Stainless steel |
Climate test |
EN60068-2-30,DB55℃/100% |
Shockproof |
EN60068-2-6, 5-500Hz,50g,10min |